Related Experiment Video
Updated: Aug 23, 2026

Sample Drift Correction Following 4D Confocal Time-lapse Imaging
Published on: April 12, 2014
Chemometric correction of drift effects in optical spectra
Frank Vogt1, Hannes Steiner, Karl Booksh
1Arizona State University, Department of Chemistry and Biochemistry, Mail stop 1604, Tempe, Arizona 85287, USA. fvogt@asu.edu
Abstract:
All quantitative data evaluation techniques applied to spectroscopy are based on the assumption that the baseline is stable in time. If this prerequisite is violated, major concentration errors can result since drifts are evaluated along with true spectroscopic features. For handling baseline drifts two improved principal component regression (PCR) methods are presented and compared to conventional Savitzky-Golay preprocessing followed by conventional PCR. The proposed drift-correction methods take advantage of baseline drifts being rather broad compared to the absorption features. The only assumption made is that drift effects can be modeled sufficiently by polynomials of user-selectable order. One correction method modifies principal components such that drifts of polynomial shape are orthogonal to the calibration model and thus cannot influence the concentration result. The second method extends the calibration model by synthetic so-called pseudo-principal components. While the principal components model the true spectral features, the pseudo-principal components describe drifts simultaneously and independently. Hence, drifts are explicitly included into the calibration and cannot cause erroneous concentration results. It is demonstrated that both correction methods are equivalently as powerful as the conventional PCR in the absence of drifts and superior if drifts are present. The overall performance--in the absence and presence of baseline drifts--of the novel methods makes them more versatile and reliable than the conventional Savitzky-Golay data preprocessing. In almost all investigated cases, the average concentration errors were significantly smaller than those obtained by Savitzky-Golay preprocessing. Furthermore, polyPCR and pPCR do not need laborious optimizations as Savitzky-Golay does for preventing suppression of relevant signal components. polyPCR demands less computation expense than Savitzky-Golay, and pPCR extracts the drift spectrum as additional qualitative information not provided by Savitzky-Golay.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
UV–Vis Spectroscopy: Beer–Lambert Law

