Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians
Eva M Staal1, Ottar K Nygård, Per Omvik
1Department of Heart Disease; Institute of Medicine, Haukeland University Hospital, Bergen, Norway.
Background:
The Keito machine offers automatic measurements of blood pressure (BP), height and weight on insertion of coins and has been introduced in pharmacies.
Design:
Cross-sectional study comparing automatic BP measurements by the Keito machine to office BP measurements by physicians.
Methods:
Patients scheduled for pre-catheterisation screening participated in the study. Their BP was first measured using the Keito machine, then by physicians. Office BP was recorded as the last of three consecutive BP measurements recorded with one-min intervals after a five-min rest in the sitting position. In a sub-study BP was measured simultaneously during the Keito measurement by a physician.
Results:
In 390 consecutive patients average BP was significantly lower with the Keito machine compared to office BP measurements made by the physicians (136/75+/-19/8 mmHg versus 141/79+/-21/10 mmHg, both p<0.001). The correlation coefficient (r) was 0.56 (p<0.001) for systolic BP (SBP) and 0.53 (p<0.001) for diastolic BP (DBP). Bland-Altman analysis showed a mean difference (+/-2 SD) for SBP and DBP of -5 (+/-37) and -4 (+/-17) mmHg, respectively. When defining hypertension (HT) as office SBP> or =140 and/or DBP> or =90 mmHg, the Keito method diagnosed 83% of the systolic and 62% of the diastolic hypertensive population correctly. The classification of systolic and diastolic normotensive was correct in 61% and 86%, respectively.
Conclusion:
Agreement between office and Keito BP is poor. The Keito machine underestimates SBP on average by 5 mmHg and DBP by 4 mmHg, which may be of significance for diagnosing HT and starting anti-hypertensive therapy. However, the difference can be much larger in individual patients. Therefore, the Keito machine cannot be recommended for medical screening of HT or as a replacement for follow-up by physicians.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure