Related Experiment Video
Updated: Aug 5, 2026

Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
Published on: April 29, 2011
The 'fixed performance' venturi: effect of downstream pressure on outflow and FIO2
1University Department of Anaesthesia, Addenbrooke's Hospital, Hills Road, Cambridge, CB2 2QQ, UK. Gareth@garjons.demon.co.uk
Abstract:
Fixed performance venturi devices should provide a predetermined oxygen concentration at an outflow which exceeds an adult's peak resting inspiratory flow rate (approximately 30 l.min(-1)). Campbell's original description mentioned the sensitivity of the venturi device to downstream resistance but gave no further details. This study examined outflow and oxygen concentration from the five standard venturi devices (24-60% O(2)) when downstream pressure increased. Outflow was exquisitely sensitive to small increases in pressure. The outflow at zero downstream pressure for the 24-40% O(2) venturi devices ranged from 40 to 50 l.min(-1) but only 2-3 mmH(2)O was needed to halve this flow and increase oxygen concentration. The 60% O(2) venturi delivered a maximum of only 30 l.min(-1) at zero downstream pressure and flow was reduced further by increasing this pressure. An increase in downstream pressure of only a few mmH(2)O increased oxygen concentration and decreased outflow of all the venturi devices tested, in most to less than normal peak tidal flow in adults.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Related Concept Videos
Bernoulli's Principle: Applications
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below:
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Free Jet
Pipe Flowrate Measurement
The orifice meter is a simple,...