Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Augmentation of dilated failing left ventricular stroke work by a physiological cardiac assist device
Amir Landesberg1, Eugene Konyukhov, Rona Shofti
1Department of Biomedical Engineering and Bruce Rappaport School of Medicine, Technion, Israel Institute of Technology, Haifa, Israel. amir@bm.technion.ac.il
Abstract:
A novel physiological cardiac assist device (PCAD), otherwise known as the LEVRAM assist device, which is synchronized with the heartbeat, was developed to assist the left ventricle (LV) in chronic heart failure (CHF). The PCAD utilizes a single cannula, which is inserted in less than 15 s through the apex of the beating LV by means of a specially designed device. Blood is withdrawn from the LV into the PCAD in diastole and is injected back to the LV, through the same cannula, during the systolic ejection phase, thereby augmenting stroke volume (SV) and stroke work (SW). CHF with dilated LV was induced in sheep by successive intracoronary injections of 100-microm beads. The sheep (92.2 +/- 25.9 kg, n = 5) developed stable CHF with increased LV end-diastolic diameter (69.4 +/- 3.3 mm) and end-diastolic volume (LVEDV = 239 +/- 32 mL), with severely reduced ejection fraction (23.8 +/- 7.6%), as well as mild-to-moderate mitral regurgitation. The sheep were anesthetized, and the heart was exposed by left thoracotomy. Pressure was measured in the LV and aorta (Millar). The SV was measured by flow meters and the LV volume by sonocrystals. Assist was provided every 10 regular beats, and the assisted beats were compared with the preceding unassisted beats, at the same LVEDV. The PCAD displaced 13.6 +/- 3.4 mL, less than 8% of LVEDV. Added SW was calculated from the assisted and control pressure-volume loops. The efficiency, defined as an increase in SW divided by the mechanical work of the PCAD, was 85.4 +/- 16.9%. We conclude that the PCAD, working with a small displaced blood volume in synchrony with the heartbeat, efficiently augments the SW of the dilated failing LV. The PCAD is suggested for use as a permanent implantable device in CHF.
More Related Videos
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure VI: Adjunct Therapies
Heart Failure II: Pathophysiology
Cardiomyopathy V: Interprofessional Care
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...