Related Experiment Video
Updated: Aug 23, 2026

Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
[Influence of effluent discharging modes on membrane fouling in a submerged membrane bioreactor]
Li Ma1, Guo-cheng Du, Jian Chen
1School of Biological Engineering, Southern Yangtze University, Wuxi 214036, China.
Abstract:
The influence of effluent discharging modes on membrane fouling in a submerged membrane bioreactor was evaluated, and the feasibility of the characterization of membrane fouling using Flundlich isothermal adsorption equation was also explored in this paper. Under the same operation conditions, the adsorption equations of three discharging modes of vacuum pump drawing combined with air back-blowing, vacuum pump drawing and suck pump drawing were 2.59ce1/0.957, 7.415ce1/1.369 and 7.10ce1/1.015. Experiment results showed that the effluent-discharging mode had a significant influence on membrane fouling in the submerged membrane bioreactor. Among three discharging modes, the membrane fouling degree in the mode of vacuum pump drawing combined with air back-blowing was the lightest. The experimental results also indicated that Flundlich isothermal adsorption equation is applicable in the characterization of membrane fouling.
Related Concept Videos
Microbial Wastewater Treatment
Biological Treatment of Effluent and Waste Water
Bioreactor Controls-II
Bioreactor Controls-I
Bioreactor Design and Operational System
Microbial Fuel Cells