Related Experiment Video
Updated: Aug 23, 2026

Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
Evaluation of three temperature measurement methods used during microwave thermotherapy of prostatic enlargement
1Department of Mechanical Engineering, Linköping University, Sweden. joawr@ikp.liu.se
Abstract:
Three temperature measurement methods used during microwave thermotherapy of prostatic enlargement are analysed and evaluated using a phantom model. A commercial transurethral microwave thermotherapy (TUMT) system that uses a radiometric thermometer for temperature control was used to heat the phantom. The transient temperature distribution was obtained by using both fibreoptic (which is considered as gold standard) and thermocouple measurements. Both methods are subject to potential measurement errors caused by electromagnetic and/or thermal interference. The error sources are analysed and the measurement methods evaluated. The radiometric temperature and especially its relation to the transient temperature distribution was evaluated based on the fibreoptic and thermocouple measurements. These measurements in principle gave equivalent temperature distributions, and thermal interference was concluded to be the largest source of measurement error. The radiometric measurement method gave qualitative rather than quantitative readings of the temperature, and an underestimation of more than 10 degrees C was obtained for some parts of the heated area. The area that gives most of the radiometric signal was relatively close to the catheter in contrast to previously published results.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
