Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
New blood volume monitoring method for hemodialysis: A-V pressure gradient measurement by synchronized one-point
Masami Oda1, Sanehiro Hokama, Kimio Sugaya
1Department of Urology, School of Medicine, University of the Ryukyus, Okinawa, Japan. oda@med.u-ryuku.ac.jp
During hemodialysis, rapid ultrafiltration often causes symptomatic hypotension. To predict the occurrence of volume-dependent hypotension as early as possible, continuous hematocrit monitoring with the Crit-Line noninvasive monitor has been widely used to measure blood volume changes during hemodialysis. As another potential method of monitoring blood volume variations, we studied blood viscosity, which is theoretically associated with the pressure gradient across the dialyzer. Blood viscosity (calculated by the Hugen-Poiseuille formula) is a major determinant of the blood flow rate and is associated with the pressure difference between the postpump arterial (A) and venous (V) pressures. The A-V pressure gradient fluctuates due to pump pulsation, so we minimized this noise by always reading the pressure gradient at the same point out of 1400 partitions on the rotary pump. To test this synchronized one-point reading method, the A-V pressure gradient was measured using 3 different xanthan gum solutions and was found to be linearly proportional to the model blood flow rate. In an experimental dialysis system using a xanthan gum solution (300 mg/L), the A-V pressure gradient showed a gradual linear increase along with the ultrafiltration rate up to 1 L/h as the viscosity slowly increased in the dialyzer. The changes of blood volume shown by this method were significantly correlated with data obtained using the Crit-Line in 8 patients undergoing hemodialysis. This simple and inexpensive method may allow monitoring of blood volume changes and thus provide data that are beneficial for fluid management in hemodialysis patients suffering from clinical dialysis intolerance.
During hemodialysis, rapid ultrafiltration often causes symptomatic hypotension. To predict the occurrence of volume-dependent hypotension as early as possible, continuous hematocrit monitoring with the Crit-Line noninvasive monitor has been widely used to measure blood volume changes during hemodialysis. As another potential method of monitoring blood volume variations, we studied blood viscosity, which is theoretically associated with the pressure gradient across the dialyzer. Blood viscosity (calculated by the Hugen-Poiseuille formula) is a major determinant of the blood flow rate and is associated with the pressure difference between the postpump arterial (A) and venous (V) pressures. The A-V pressure gradient fluctuates due to pump pulsation, so we minimized this noise by always reading the pressure gradient at the same point out of 1400 partitions on the rotary pump. To test this synchronized one-point reading method, the A-V pressure gradient was measured using 3 different xanthan gum solutions and was found to be linearly proportional to the model blood flow rate. In an experimental dialysis system using a xanthan gum solution (300 mg/L), the A-V pressure gradient showed a gradual linear increase along with the ultrafiltration rate up to 1 L/h as the viscosity slowly increased in the dialyzer. The changes of blood volume shown by this method were significantly correlated with data obtained using the Crit-Line in 8 patients undergoing hemodialysis. This simple and inexpensive method may allow monitoring of blood volume changes and thus provide data that are beneficial for fluid management in hemodialysis patients suffering from clinical dialysis intolerance.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement