Related Experiment Video
Updated: May 2, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
On-line preconcentration for capillary electrophoresis-atomic fluorescence spectrometric determination of arsenic
1Central Laboratory, Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin, China. xbyin@ns.ciac.jl.cn
Abstract:
An on-line preconcentration method was developed for capillary electrophoresis (CE) with hydride generation-atomic fluorescence spectrometric (HG-AFS) detection of arsenite, arsenate, dimethylarsenic acid, and monomethylarsenic acid. These arsenic species were negatively charged in the sample solution with high pH. When the potential was applied to the electrophoretic capillary, the negatively charged analyte ions moved faster and stacked at the boundary of sample and CE buffer with low pH. So, high sample pH in combination with low buffer pH allowed the injection of large sample volumes (approximately 1100 nL). Comparison of the preconcentration of analyte solution, prepared with doubly deionized water and that prepared with lake or river water, indicated that preconcentration was independent on the original matrix. With injection of approximately 1100 nL sample, an enrichment factor of 37-50-fold was achieved for the four species. Detection limits for the four arsenic species ranged from 5.0 to 9.3 microg.L(-1). Precisions (RSDs, n = 5) were in the range of 4.9-6.7% for migration time, 4.7-11% for peak area, and 4.3-7.1% for peak height, respectively. The recoveries of the four species in locally collected water solution spiked with 0.1 microg.mL(-1) (as As) ranged from 83 to 109%.
More Related Videos
08:01Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Lab
Atomic Fluorescence Spectroscopy