Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Blood pressure measurement in dialysis patients
Niranjan Sankaranarayanan1, Sergio F F Santos, Aldo J Peixoto
1Division of Nephrology, University of Connecticut School of Medicine, Farmington, CT, USA.
Abstract:
The best method and timing of blood pressure (BP) measurement in end-stage renal disease are subject to controversy. This issue is especially relevant in hemodialysis patients, where unique causes of inaccuracy may exist. The lack of standardization of BP measurement in the dialysis unit may lead to misdiagnosis, so close attention must be paid to technical methods to obtain BP. A composite of BP measurements over a period of 1 to 2 weeks rather than isolated readings should be used for guidance. Interdialytic BP monitoring with an ambulatory BP monitor is the most reproducible method and is thought to best represent BP in dialysis patients. If available, ambulatory BP is a useful tool to evaluate the quality of BP control in the interdialytic period. Alternative forms of BP measurement, such as home BP, 20-minute postdialysis BP, and short (3-hour to 4-hour) ambulatory blood pressure monitoring (ABPM), could prove useful when feasible or available. In this paper, we discuss the evidence regarding BP measurement in dialysis patients, new techniques under development, and recommendations for clinical practice.
Related Concept Videos
Hemodialysis III: Nursing Management
Hemodialysis II: Procedure and Complications
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...