Related Experiment Video
Updated: Aug 23, 2026

Surface Electromyographic Biofeedback as a Rehabilitation Tool for Patients with Global Brachial Plexus Injury Receiving Bionic Reconstruction
Published on: September 28, 2019
Time sequence of sensory changes after upper extremity block: swelling sensation is an early and accurate predictor
Xavier Paqueron1, Marc E Gentili, Jean Claude Willer
1Department of Anesthesiology, Centre Hospitalo-Universitaire Pitié-Salpêtrière, France. xavier.paqueron@psl.ap-hop-paris.fr
Background:
Sensory assessment to estimate spread and effectiveness of a peripheral nerve block is difficult because no clinical test is specific for small sensory fibers. Occurrence of a swelling illusion (SI) during a peripheral nerve block corresponds to the impairment of small sensory fibers. The authors investigated the usefulness of SI in predicting successful peripheral nerve block by assessing the temporospatial correlation between progression of sensory impairment in cutaneous distributions anesthetized and localization of SI during peripheral nerve block installation.
Methods:
Interscalene, infracoracoid, or sciatic nerve blocks were performed using a nerve stimulator and 1.5% mepivacaine in 53 patients, with a total of 201 nerves to be anesthetized. Pinprick, cold, warm, touch, and proprioception were assessed every 3 min, while patients were asked to describe their perception of size and shape of their anesthetized limb and localization of these illusions. Data are presented as mean +/- SD and percentage (95% confidence interval).
Results:
Failure occurred in 12 cutaneous distributions out of a total of 201 theoretically blocked nerves. SI appeared earlier than warmth impairment (4.3 +/- 2.7 vs. 6.2 +/- 2.0 min; P < 0.05), always corresponding to successfully anesthetized cutaneous distributions, with the exception of 1 patient, who developed SI in 2 cutaneous distributions while sensory testing indicated failure in 1 distribution. SI successfully predicted the blockade of a cutaneous distribution with a sensitivity of 1.00 (0.98-1.00), a specificity of 0.92 (0.65-0.99), and an accuracy of 0.99 (0.97-1.00).
Conclusions:
Swelling illusion may provide an early assessment of the success of a peripheral nerve block in unsedated patients.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Peripheral Artery Disease V: Postoperative Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...