Background:
S100beta has been used in cardiac surgery to identify patients with postoperative neurologic complications. However, extracranial proteins may falsely elevate measurements of serum S100beta;. Objectives of this study were (1) to quantify S100 beta levels in serum and pericardial cavity during coronary artery bypass grafting (CABG), and (2) to identify proteins recognized by standard immunodetection as S100beta.
Methods:
Systemic and pericardial cavity blood from 5 patients undergoing CABG were sampled before, during, and after cardiopulmonary bypass (CPB). A commercially available enzyme-linked immunosorbent assay (ELISA) kit was used to quantify S100beta. Two-dimensional gel electrophoresis, Western blot, and mass spectroscopy were also performed to identify S100a and other proteins.
Results:
Mean S100beta levels measured by ELISA, systemic and pericardial cavity blood were (in ng x mL(-1)) 1.0 +/- 0.46 and 111 +/- 71 before CPB, 0.6 +/- 0.11 and 113 +/- 54 during CPB, and 1.7 +/- 0.64 and 101 +/- 42 after CPB, respectively. However, gel electrophoresis and Western blot analysis revealed proteins other than S100beta to be present in the pericardial cavity giving a falsely elevated serum S100a levels measured by immunoassay. Mass spectroscopy of identified potential candidates revealed contaminants including haptoglobin I precursor, apolipoprotein A-1 precursor, complement factor B precursor, and complement C3 precursor.
Conclusions:
S100beta immunoassays are not specific for S100a and give a falsely elevated reading due to contaminants from the surgical field that cross react with the assay's antibody. This does not appear to be an issue in nonsurgical patients. Caution must be exerted when evaluating immunodetection results for low-abundance proteins under conditions where contamination of the sample is likely.
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...