Related Experiment Video
Updated: Aug 23, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
Preliminary experience with GORE-TEX grafting for right ventricle-pulmonary artery conduits
1Department of Surgery, University of Minnesota, Minneapolis, Minnesota 55455, USA.
Abstract:
A consecutive series of 12 patients between the ages of 6 1/2 and 37 years underwent implantation of venous ventricle-pulmonary artery conduits. GORE-TEX material without prosthetic valves was used. Four patients had L-transposition of the great vessels with ventricular septal defect (VSD) and pulmonary stenosis; four had tetralogy of Fallot with pulmonary atresia; and one had double outlet right ventricle, pulmonary stenosis, and a complete form of A-V canal. Two patients had D-transposition of the great arteries, VSD, and pulmonary stenosis; and one patient had L-transposition of the great arteries and isolated pulmonary stenosis. All patients had low pulmonary resistance and pressures. The technique for implanting this noncrimped type of prosthesis is described in detail. Follow-up ranged from 2 months to 5 1/2 years. GORE-TEX offers a good choice of material for the construction of this type of conduit to prevent pseudointima formation and obstruction, which is often observed in woven Dacron grafts.