Pacemaker associated infection due to a corynebacterium species
Related Experiment Video
Updated: Aug 23, 2026

Visualization of Streptococcus pneumoniae within Cardiac Microlesions and Subsequent Cardiac Remodeling
Published on: April 7, 2015
M Klima1, J Clarridge, A Chapman
1Laboratory Service and Section of Infectious Diseases, Veterans Administration Medical Center, Houston, Texas 77030, USA.
Abstract:
Pacemaker associated infection (PAI) is a rare but often serious complication of permanent or temporary transvenous cardiac pacemakers. The major risk factor is recent or multiple pacemaker manipulations or surgical procedures. A PAI can occur at the time of insertion, from contiguous spread to the access site, or from transient bacteremia. We report a case of PAI of a retained pacemaker electrode from which a Corynebacterium species was isolated. Multiple preoperative cultures were sterile, but bacteria were isolated from tissue removed at surgery, and were seen around the wire deep inside a thrombus. The importance of cultures and special stains (including electron microscopy) of surgical materials is stressed, especially when dealing with microorganisms of ordinarily low virulence, or those that are commonly considered laboratory contaminants.
Insights
Pacemaker associated infection (PAI) is a rare complication. This case highlights Corynebacterium infection from a retained pacemaker electrode, emphasizing diagnostic importance.
Area of Science:
- Cardiology
- Infectious Diseases
- Medical Device Complications
Background:
- Pacemaker associated infection (PAI) is a rare but serious complication of cardiac pacemakers.
- Risk factors include recent pacemaker manipulations or surgical procedures.
- PAI can arise during insertion, from local spread, or transient bacteremia.
Purpose of the Study:
- To report a case of PAI caused by a retained pacemaker electrode.
- To highlight the diagnostic challenges and importance of microbiological analysis in PAI.
Main Methods:
- Case report of a patient with PAI.
- Isolation of Corynebacterium species from surgical tissue and thrombus around the retained electrode.
- Use of cultures and special stains, including electron microscopy.
Main Results:
- Corynebacterium species was isolated from the retained pacemaker electrode and surrounding thrombus.
- Preoperative cultures were sterile, indicating the challenge in early diagnosis.
- Microorganisms were visualized around the wire deep within the thrombus.
Conclusions:
- Retained pacemaker electrodes can harbor microorganisms, leading to PAI.
- Cultures and special stains of surgical materials are crucial for diagnosing PAI, especially with low-virulence organisms.
- This case underscores the need for thorough investigation in suspected PAI cases.