Effect of buffer on peak shape of peptides in reversed-phase high performance liquid chromatography
1Faculty of Applied Sciences, Centre for Research in Biomedicine, Frenchay Campus, University of the West of England, Coldharbour Lane, Bristol BS16 1QY, UK. david.mccalley@uwe.ac.uk
Abstract:
The effect of changing the buffer at constant low pH in the mobile phase is investigated with respect to the separation of a mixture of basic peptides. Considerably worse peak shapes, leading to poorer resolution of complex peptide mixtures, were obtained when using formic acid favoured in LC-MS applications compared with non volatile phosphate buffers or with trifluoroacetic acid (TFA). Poorer peak shapes were largely attributable to reduced column capacity for the peptides when using mobile phases of low ionic strength, due to the increased mutual repulsion of ions held on the hydrophobic column surface which is facilitated in these buffers. However, ion-pairing between the peptides and additives such as TFA or even phosphate may also lessen mutual repulsion effects, leading to greater column capacity. Overloading effects could be observed when sample masses around only 0.1 microg were injected on to standard size analytical columns in formic acid containing mobile phases; sample masses around only 1.5 microg may cause loss of half the system peak capacity in such mobile phases. Results were broadly comparable (after scaling sample size according to column diameter) on columns of both conventional (4.6 mm i.d.) and capillary (0.075 mm i.d.) dimensions. Ammonium formate may be a useful alternative buffer for some applications due to its higher ionic strength.
More Related Videos
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
08:232 in 1: One-step Affinity Purification for the Parallel Analysis of Protein-Protein and Protein-Metabolite Complexes
Published on: August 6, 2018
Related Concept Videos
Chromatographic Methods: Terminology
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...