Modeling of arterial stenosis and its applications to blood diseases
1Faculty of Applied Mathematics, Institute of Armament Technology, Girinagar, Pune 411 025, Maharashtra, India. dr_mpralhad@yahoo.com
Abstract:
Blood flow in a stenosed tube has been modeled in the present studies. Blood flow is assumed to be represented by a couple stress fluid. Flow parameters such as velocity, resistance to flow, and shear stress distribution have been computed for different suspension concentrations (haematocrit), and for the blood diseases; polycythemia, plasma cell dyscrasias, and for Hb SS (sickle cell). The results have been compared with the case of normal blood and for other theoretical models. The importance of size effects in blood flow studies has been highlighted.