Regression of coronary atherosclerosis by simvastatin: a serial intravascular ultrasound study
Lisette Okkels Jensen1, Per Thayssen, Knud Erik Pedersen
1Department of Cardiology, Catheterization Laboratorium, Odense University Hospital, Odense, Denmark. okkels@dadlnet.dk
Background:
Angiography of the coronary arteries reflects only changes in luminal dimensions. With intravascular ultrasound, cross-sectional images can be obtained and area measurements can be added to calculate volumes of the external elastic membrane (EEM), plaque plus media (P+M), and lumen. The aim of this study was to investigate the effect of lipid lowering by simvastatin on coronary atherosclerotic P+M as changes in volumes of EEM, P+M, and lumen.
Methods And Results:
In 40 male patients with hypercholesterolemia, ischemic heart disease, and a nonsignificant coronary artery lesion in a not previously revascularized coronary artery, serial intravascular ultrasound studies with an ECG-triggered pullback were performed at baseline, after 3 months on a lipid-lowering diet, and after another 12 months on simvastatin 40 mg/d. Mean length of the analyzed atherosclerotic segments was 5.9+/-3.3 mm. After 12 months on simvastatin, a significant reduction in P+M volume of 6.3% (P=0.002) was observed, whereas only a nonsignificant reduction in EEM volume of 1.8% was seen without any concomitant change in lumen volume. A significant reduction in total cholesterol of 31.0% (6.1+/-0.8 versus 4.2+/-0.7 mmol/L, P<0.001) and LDL cholesterol of 42.6% (4.0+/-0.8 versus 2.2+/-0.6 mmol/L, P<0.001) was obtained.
Conclusions:
Lipid-lowering therapy with simvastatin for 12 months is associated with a significant P+M regression in coronary arteries measured as reduction in P+M and EEM volumes without any concomitant change in lumen volume.
More Related Videos
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Atherosclerosis III: Management
Coronary Artery Disease II: Pathophysiology
Coronary Artery Disease I: Introduction
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies
Coronary Artery Disease IV: Preventive Measures