Related Experiment Video
Updated: Aug 23, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Headspace solid phase microextraction for the gas chromatographic analysis of methyl-parathion in post-mortem human
H Tsoukali1, N Raikos, G Theodoridis
1Laboratory of Forensic Medicine and Toxicology, Faculty of Medicine, Aristotle University, 541 24 Thessaloniki, Greece. elpa@med.auth.gr
Abstract:
A simple and rapid procedure for the determination of methyl-parathion (m-p) in post-mortem biological samples was developed using headspace solid phase microextraction (SPME) and gas chromatography (GC) with nitrogen-phosphorous detection (NPD). Methyl-parathion was extracted on 85 microm polyacrylate SPME fiber. Salt addition, extraction temperature, and extraction time were optimized to enhance the sensitivity of the method. The linearity (y = 0.0473x - 0.0113, R2 = 0.9992) and the dynamic range (0.1-40 microg/ml) were found very satisfactory. The recoveries of methyl-parathion were found to be 46% in spiked human whole blood, 53% in spiked homogenized liver tissue, and 54% in spiked homogenized kidney tissue compared with samples prepared in water. The coefficients of variations for 2, 4, and 20 microg/ml of methyl-parathion in blood ranged from 0.9 to 5.1%, whereas the detection limit of the method was satisfactory (1 ng/ml in aqueous samples, 50 ng/ml in whole blood). The developed procedure was applied to post-mortem biological samples from a 21-year-old woman fatally poisoned (suicide) by intravenous injection of methyl-parathion. The intact insecticide was found in the post-mortem blood at a concentration of 24 microg/ml. No methyl-parathion was detected in the liver, kidneys, and gastric contents.
More Related Videos
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.