Related Experiment Video
Updated: Aug 23, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Effect of prolongation of expiratory time on dynamic hyperinflation in mechanically ventilated patients with severe
James W Leatherman1, Charles McArthur, Robert S Shapiro
1Division of Pulmonary and Critical Care Medicine, Hennepin County Medical Center, Minneapolis, MN, USA.
Objective:
To assess the effect of a decrease in respiratory rate on dynamic hyperinflation, as determined by changes in plateau airway pressure, in patients with status asthmaticus whose baseline minute ventilation approximated 10 L/min.
Design:
Observational descriptive study.
Setting:
Medical intensive care unit.
Patients:
Twelve patients with severe asthma mechanically ventilated in the assist control mode with a tidal volume of 613 +/- 100 mL and an inspiratory flow rate of 79 +/- 4 L/min.
Interventions:
A decrease in respiratory rate from 18 to 12 and 6 breaths/min.
Measurements And Main Results:
Plateau airway pressure decreased by approximately 2 cm H2O (25.4 +/- 2.8 vs. 23.3 +/- 2.6 cm H2O, p <.01) when respiratory rate was decreased from 18 to 12 breaths/min (increase in expiratory time 1.7 secs) and by a similar amount (23.3 +/- 2.6 vs. 21.3 +/- 2.9 cm H2O, p <.01) when respiratory rate was decreased from 12 to 6 breaths/min (increase in expiratory time 5 secs). Peak airway pressure was similar at the three respiratory rates (66.8 +/- 8.7 vs. 66.4 +/- 9.5 vs. 67.8 +/- 11.1 cm H2O at 18, 12, and 6 breaths/min, respectively). End-expiratory flow rates (n = 7) were 61.4 +/- 12.6, 38.6 +/- 4.5, and 23.1 +/- 5.8 mL/sec at respiratory rates of 18, 12, and 6 breaths/min, respectively.
Conclusions:
Prolongation of expiratory time decreases dynamic hyperinflation in patients with status asthmaticus, as evidenced by a reduction in plateau airway pressure, but the magnitude of this effect is relatively modest when baseline minute ventilation is < or = 10 L/min, because of the low end-expiratory flow rates. Since flow progressively decreases throughout expiration, the reduction in dynamic hyperinflation resulting from a given prolongation of expiratory time will depend on the baseline respiratory rate (i.e., less reduction in dynamic hyperinflation at a lower respiratory rate). Changes in peak airway pressure may not always reflect the changes in dynamic hyperinflation that result from prolongation of expiratory time.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-III
Mechanical Ventilation I: Indication and Settings
Pulmonary Cycle: Exhalation
Hyperpnea and Hyperventilation
Atelectasis II: Pathophysiology