Integrated Compensatory Responses in a Human Model of Hemorrhage
Published on: November 20, 2016
Stroke volume monitored by modeling flow from finger arterial pressure waves mirrors blood volume withdrawn by
Pascal Leonetti1, Françoise Audat, Arlette Girard
1Unité de Pharmacologie Clinique, INSERM E107, 75743 Paris Cedex 15, France.
Rate-controlled blood withdrawal was used to reduce cardiac preload and consequently stroke volume in patients with normal cardiac function. Twelve patients with asymptomatic hereditary hemochromatosis, undergoing regular phlebotomy therapy, volunteered for the study. An average volume of 375 ml was withdrawn in an average period of 6.4 min. Finger pressure was continuously measured by a Finometer device which includes the Beatscope software for deriving the stroke volume from the blood pressure waveform. Blood withdrawal resulted in reduction of the stroke volume estimates (from 94.0 +/- 5.2 to 80.7 +/- 5.3, P < 0.05) together with a reduced pulse pressure (from 53.0 +/- 3.5 to 47.1 +/- 3.2, P < 0.05). No significant changes in heart rate (75.2 +/- 3.7 versus 78.3 +/- 4.5 beats/min) were observed. Calculated cardiac output was reduced while calculated total peripheral resistance was elevated after blood withdrawal. Beat-to-beat analysis demonstrated a significant linear regression between most of the hemodynamic indices and the volume withdrawn. The highest correlation coefficients were found for the stroke volume (0.88 +/- 0.01, P < 0.001) and the pulse pressure (0.80 +/- 0.04, P < 0.001) corresponding also to the highest slopes for the lines relating these measures to the relative blood volume withdrawn. The non-invasive estimation of finger blood pressure can be used to derive simple on-line indices (pulse pressure, stroke volume using the Modelflow) of cardiac preload, which are of major interest in the monitoring of cardiovascular status.
Rate-controlled blood withdrawal was used to reduce cardiac preload and consequently stroke volume in patients with normal cardiac function. Twelve patients with asymptomatic hereditary hemochromatosis, undergoing regular phlebotomy therapy, volunteered for the study. An average volume of 375 ml was withdrawn in an average period of 6.4 min. Finger pressure was continuously measured by a Finometer device which includes the Beatscope software for deriving the stroke volume from the blood pressure waveform. Blood withdrawal resulted in reduction of the stroke volume estimates (from 94.0 +/- 5.2 to 80.7 +/- 5.3, P < 0.05) together with a reduced pulse pressure (from 53.0 +/- 3.5 to 47.1 +/- 3.2, P < 0.05). No significant changes in heart rate (75.2 +/- 3.7 versus 78.3 +/- 4.5 beats/min) were observed. Calculated cardiac output was reduced while calculated total peripheral resistance was elevated after blood withdrawal. Beat-to-beat analysis demonstrated a significant linear regression between most of the hemodynamic indices and the volume withdrawn. The highest correlation coefficients were found for the stroke volume (0.88 +/- 0.01, P < 0.001) and the pulse pressure (0.80 +/- 0.04, P < 0.001) corresponding also to the highest slopes for the lines relating these measures to the relative blood volume withdrawn. The non-invasive estimation of finger blood pressure can be used to derive simple on-line indices (pulse pressure, stroke volume using the Modelflow) of cardiac preload, which are of major interest in the monitoring of cardiovascular status.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Pre-Procedural Guidelines for Assessing Blood Pressure