Symptom Assessment of Patients with Allergic Rhinitis Using an Allergen Exposure Chamber
Published on: March 3, 2023
Nasal conditioning in perennial allergic rhinitis after nasal allergen challenge
A Rozsasi1, R Leiacker, T Keck
1Department of Otorhinolaryngology, University of Ulm, Ulm, Germany. ajnirozsasi@hotmail.com
Background:
Antigen challenge in seasonal allergic rhinitis is considered to be associated with an increased ability of the nose to condition inspired air. In contrast, little is known about air conditioning after antigen challenge in perennial allergic rhinitis (PAR).
Objective:
The aims of this study were to investigate whether antigen challenge in PAR changes nasal air conditioning and to assess the relationship between nasal conditioning and nasal patency and geometry.
Methods:
Nineteen subjects with PAR were enrolled into this study. Measurement of nasal conditioning, active anterior rhinomanometry (AAR), acoustic rhinometry (AR), and clinical symptom evaluation were performed before and after nasal allergen challenge with allergen extracts from house dust mites.
Results:
Ten and 20 min after nasal allergen challenge, the total water content of the air measured in the nasopharynx and the water gradient across the nose were significantly higher in the nasal cavity in which the allergen extract was sprayed. The temperature on both sides of the nose increased non-significantly after nasal allergen challenge. No correlation to data obtained by AAR, AR, and clinical symptom evaluation after nasal allergen challenge was found.
Conclusion:
We suggest that an increase in mucosal humidity due to the allergic provocation might be responsible for the increase in nasal conditioning capacity because no correlation to changes in nasal perimeter and patency was found.
More Related Videos
06:08Immunofluorescent Labeling in Nasal Mucosa Tissue Sections of Allergic Rhinitis Rats via Multicolor Immunoassay
Published on: September 22, 2023
11:54Absorption of Nasal and Bronchial Fluids: Precision Sampling of the Human Respiratory Mucosa and Laboratory Processing of Samples
Published on: January 21, 2018
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Nose and Nasal Cavity