IR ear thermometers: what do they measure and how do they comply with the EU technical regulation?
Igor Pusnik1, Eric van der Ham, Janko Drnovsek
1Faculty of Electrical Engineering, Laboratory of Metrology and Quality, University of Ljubljana, Trzaska 25, 1000 Ljubljana, Slovenia. igor.pusnik@fe.uni-lj.si
Abstract:
Medical diagnostics and clinical practice rely extensively on test and measurement instrumentation. It is therefore of paramount importance that test and measurement instrumentation provides reliable data of sufficient stability, within appropriate limits of accuracy. At the same time the intended purpose of a particular measuring instrument has to be taken into account. The essential problem of every measuring instrument is that it measures and indicates basically what appears at the input of the measuring instrument, which might be significantly different from the real condition of a measurand. Namely, it is assumed that a measurand is stable, repeatable, and relatively unsusceptible to environmental influences. All these requirements are difficult to assure in a biological system and especially difficult in medical practice. Technology could easily provide high-resolution measurements, but due to natural instability of a measurand and various influential parameters the measurement uncertainty is inevitable. Sometimes even gross measurement errors are introduced. To achieve the expected accuracy for intended purpose is therefore much more demanding than merely relying on manufacturers' specifications. This paper describes and analyses the mentioned dilemmas in the case of widely used infrared ear thermometers, with their benefits and limitations, as well as with regard to the European technical regulation in the field of medical devices.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...