Related Experiment Video
Updated: Jul 27, 2026

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Options for the modified radiation weighting factor of neutrons
A M Kellerer1, G Leuthold, V Mares
1Radiobiological Institute, University of Munich, Schillerstrasse 42, D-80336 Munich, Germany. AMK.SBI@LRZ.uni-muenchen
Abstract:
The recent ICRP Report 92 has noted that the current radiation weighting factor, wR, depends on the energy of the incident neutrons in a manner that differs substantially from the dependence, which results from the current convention, QL. At all neutron energies, but most conspicuously below 1 MeV, the values of wR exceed those of the effective quality factor, qE. The discrepancy is largely due to the fact that--in the absence of computed values of the effective quality factor for neutrons--wR has been patterned after the values of the ambient quality factor, which accounts insufficiently for the low-linear energy transfer (LET) gamma ray component from neutron capture in the human body. There are different options to remove the discrepancy. Option 1 is to reduce wR substantially at all neutron energies to make it equal to qE for a standard condition, such as isotropic incidence of the neutrons. Since such a reduction may cause problems in those countries where the current wR values are already legally implemented, ICRP 92 has proposed what is here termed Option 2. It recommended to replace QL by the increased value 1.6 QL - 0.6 and, accordingly, to make the radiation weighting factor equal to 1.6 qE - 0.6. With Option 2 the radiation weighting factor needs to be decreased appreciably at low neutron energies, but for fission neutron spectra the overall changes are minor. To guide--regardless which option is chosen--the selection of the numerical values, the effective quality factor, qE, is computed here for different directional distributions of neutrons incident on the anthropomorphic phantoms ADAM and EVA. None of the sex averaged numerical values is found to deviate much from those for isotropic incidence. Isotropic incidence can, thus, be used as an adequate standard condition. A numerical approximation is proposed for the standard qE that is nearly equivalent to a formula invoked by ICRP 92, but is somewhat simpler and provides realistic values of qE even for the extremely high neutron energies in space. In line with ICRP 92, it is emphasised that wR needs to be seen as a derived quantity related to the LET-dependent weighting factor.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:10Neutron Crystallography Data Collection and Processing for Modelling Hydrogen Atoms in Protein Structures
Published on: December 1, 2020
Related Concept Videos
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:
Nuclear Fission
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Nuclear Transmutation
Biological Effects of Radiation
Isotopes and Radioisotopes
An isotope containing more...