The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution
G T Burstein1, C Liu, R M Souto
1Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ, UK. gtb1000@cus.cam.ac.uk
Abstract:
This paper describes the effect of temperature on the nucleation of corrosion pits on titanium microelectrodes in Ringer's physiological solution. The results are shown for potentials far below the pitting potential, and describe breakdown of passivity with no permanent propagation of pits. Nucleation events could be observed at all the temperatures used, although they were very rare events at 20 degrees C. The frequency of breakdown rises significantly with increase in temperature. Examples are shown of current transients due to both pit nucleation and to metastable pit propagation, the latter being rare events. Analysis shows that these events constitute a significant fraction of the passive corrosion rate of titanium.
More Related Videos
12:18Co-localizing Kelvin Probe Force Microscopy with Other Microscopies and Spectroscopies: Selected Applications in Corrosion Characterization of Alloys
Published on: June 27, 2022
07:05In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Related Concept Videos
Le Chatelier's Principle: Changing Temperature
To understand this phenomenon, consider the elementary reaction:
Effects of Temperature on Free Energy
Corrosion
Precipitation Titration Curve: Analysis
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...