Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model
Published on: September 14, 2009
Noninvasive evaluation of coronary artery stents patency after PTCA: role of Multislice Computed Tomography
Guido Ligabue1, Rosario Rossi, Carlo Ratti
1Cattedra e Servizio di Radiologia 1, Azienda Ospedaliera Policlinico di Modena, Università degli Studi di Modena e Reggio Emilia.
Insights
Multi-slice CT (msCT) shows promise for follow-up of coronary artery stents larger than 3.5 mm, especially in the left anterior descending artery. However, evaluating smaller stents or those in the circumflex and right coronary arteries remains challenging with current msCT technology.
Area of Science:
- Cardiovascular Imaging
- Interventional Cardiology
- Radiology
Background:
- Coronary artery restenosis after stent implantation necessitates regular patient monitoring.
- Multi-slice CT (msCT) use is increasing for coronary artery disease, but its limitations require definition.
- Assessing the efficacy of msCT in post-angioplasty follow-up is crucial.
Purpose of the Study:
- To evaluate the role and effectiveness of Multi-slice CT (msCT) in the follow-up of patients who have undergone coronary angioplasty with stent implantation.
- To determine the indications and limitations of msCT in assessing stented coronary arteries.
Main Methods:
- A study involving 48 patients (72 lesions) who received slotted tube stents.
- msCT examinations were performed one week prior to scheduled coronary angiography for comparison.
- Analysis focused on stent location (left anterior descending, right coronary, circumflex) and size.
Main Results:
- Coronary angiography detected significant in-stent restenosis or occlusion in 16.7% of stents.
- msCT provided easier lumen visualization for LAD stents (82.4%) compared to circumflex (76.5%) and right coronary arteries (52.4%).
- Accurate visualization was higher for stents >3.5 mm (93.3%) and in the proximal LAD (OR 4.03), compared to smaller stents (33.3% for <3 mm).
Conclusions:
- Current msCT technology faces challenges in evaluating smaller stents (<3.5 mm) and those in the right coronary and circumflex arteries.
- msCT shows promise as a follow-up tool for larger stents (>3.5 mm), particularly in the proximal left anterior descending artery.
- Further technological advancements may improve msCT's utility in complex coronary stenting scenarios.
Purpose:
Restenosis of a coronary artery treated with stent implantation is a well-known process that can compromise over time the success of a coronary angioplasty and, accordingly, treated patients must undergo periodic controls. We have recently witnessed a shift towards a greater use of Multi-slice CT (msCT) in the study of coronary disease without its precise indications and limits having yet been underlined. The purpose of our study is to assess the role of msCT in the follow-up of patients treated with coronary angioplasty.
Materials And Methods:
Forty-eight patients, for a total of 72 lesions, who underwent treatment with a slotted tube stent implant, had an msCT examination 1 week before scheduled coronary angiography, and the results were compared. 34 stents/72 (47.2%) were inserted on the left anterior descending; 21/72 (29.2%) on the right coronary; 17/72 (23.6%) on the circumflex artery or obtuse marginal branches.
Results:
The observation of the opacification of the vessel located distally to treated segments allowed us to assess the patency of all stents. Coronary angiography identified a significant intrastent restenosis or a stent occlusion in 12 of the 72 stents analysed (16.7%). msCT enabled easier visualization of the lumen of the treated artery and its differentiation from the stent struts in the ones located on the left anterior descending artery than those on the circumflex (28 stents out of 34 [82.4%] vs 13/17 [76.5%]; p<0.05), and on the right coronary artery, which were difficult to evaluate (11/21 [52.4%]). We were also able to visualize the lumen of 14/15 stents with a calibre over 3.5 mm [93.3%] vs 35/45 stent with dimensions between 3.1 e 3.4 mm [77.8%], and only 4 stents <3 mm/12 [33.3%]. On multivariate analysis, the characteristics that were significantly and independently associated with accurate visualization of the lumen of a stented vessel were location on the proximal anterior descending artery (OR 4.03 [IC 95%: from 2.34 to 8.05]; p<0.0001) and stent size of >3.5 mm (OR 2.97 [IC 95%: from 1.67 to 4.86]; p<0.01).
Conclusions:
The msCT technology available at present makes the study of smaller stents and those positioned on the right coronary artery and circumflex rather complex; on the other hand msCT appears a promising study method for stents greater then 3.5 mm and for those positioned on the proximal segment of the left anterior descending artery.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI