Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
LiF:W as a scintillator for dosimetry in diagnostic radiology
1Institute for Biomedical Engineering and Physics, Medical University Vienna, AKH-4L, A-1090 Vienna, Austria. r.nowotny@bmtp.akh-wien.ac.at
Abstract:
The use of ionization chambers in diagnostic radiology is not feasible in measurement situations requiring small and robust dose sensors. The composition of LiF:W developed as a scintillator for the measurement of thermal neutrons seems profitable for an application in dosimetry of low-energy photons. Properties of a small LiF:W scintillator were determined with DV- and DH-standard radiation qualities. For a tube voltage range of 40 to 150 kV (corresponding to a HVL of 1.56 to 13.69 mm Al) a maximum variation in sensitivity of +/-13% was determined for a scintillator thickness of 3.7 mm. The scintillator signal was linear in a range from 6.6 mGy min(-1) to at least 13.7 Gy min(-1). Higher dose rates could not be obtained in the measurement setup. The temperature dependence of the luminescence response was found to decrease from +3.7% (at +2.5 degrees C) to -7.0% (at +45 degrees C) with respect to the luminescence response at 20 degrees C. LiF:W appears to be an interesting choice as a dosimetric scintillator in diagnostic radiology making immediate measurements of dose and dose rate with high spatial resolution feasible.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...