Detection of colorectal polyps by multislice CT colonography with ultra-low-dose technique: comparison with
Christoph Vogt1, Mathias Cohnen, Andreas Beck
1Division of Medicine, Department of Gastroenterology, Hepatology and Infectious Diseases, Institute of Diagnostic Radiology, Heinrich-Heine-University of Düsseldorf, Moorenstrasse 5, D-40225 Düsseldorf, Germany.
Background:
This prospective study compared multislice CT colonography with ultra-low-dose technique to high-resolution videocolonoscopy as the standard for detection of colorectal cancer and polyps.
Methods:
After standard bowel preparation, 115 patients underwent multislice CT colonography with an ultra-low-dose multislice CT colonography protocol immediately before videocolonoscopy. After noise reduction by using a mathematical algorithm, ultra-low-dose multislice CT colonographic images were analyzed in blinded fashion, and the results were compared with the results of high-resolution videocolonoscopy.
Results:
A total of 150 lesions were detected by high-resolution videocolonoscopy in 115 patients. For ultra-low-dose multislice CT colonography, sensitivities for detection of polyps less than 5 mm in size, 5 to 10 mm, and greater than 10 mm in diameter were 76%, 91%, and 100%, respectively. Although the sensitivity for detection of flat lesions was only 50%, the sensitivity and the specificity for detection of polyps 5 mm or greater in size were 94% and 84%, respectively. For adenomatous lesions greater than 5 mm in size, sensitivity was 94% and specificity was 92%. The overall specificity was 79%. The calculated effective radiation dose ranged between 0.75 and 1.25 mSv.
Conclusions:
Compared with high-resolution videocolonoscopy, ultra-low-dose multislice CT colonography has excellent sensitivity and specificity for detection of colorectal lesions 5 mm or greater in size, and the radiation exposure is relatively low. However, before this technique can be generally recommended for colorectal screening, further improvement in the detection of flat and extremely small lesions must be achieved.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...