Related Experiment Video
Updated: Aug 23, 2026

Cavernous Nerve Stimulation and Recording of Intracavernous Pressure in a Rat
Published on: April 23, 2018
Blood pressure, heart rate and catecholamine response during fiberoptic nasotracheal intubation under general
T Tsubaki1, K Aono, T Nakajima
1Department of Anesthesiology, Kokura National Hospital, Kitakyushu, Japan.
Abstract:
Arterial blood pressure (ABP) and heart rate were recorded at one-minute intervals during several stages of intubation in the fiberscope group and the laryngoscope group, to determine if fiberoptic nasotracheal intubation would result in fewer hemodynamic and catecholamine responses than when intubation was performed with a Macintosh laryngoscope. Blood samples were also taken to measure plasma catecholamine concentration immediately after intubation with the fiberscope. The mean ABP in the laryngoscope group was slightly greater than that of the fiberscope group for 4 min after intubation. Heart rates at 2 min and 4 min after intubation in the laryngoscope group were significantly greater than those for the fiberscope group. Even immediately after intubation, the mean plasma levels of epinephrine and norepinephrine were unchanged in the fiberscope group. Arterial oxygen saturation (Sp(O)(2)) was maintained within normal range during both of intubation procedures, although the time required for intubation was longer than in the laryngoscope group. Other cardiovascular complications were more common in the laryngoscope group than in the fiberscope group. These results suggest that fiberoptic intubation results in less severe stress than does laryngoscopic intubation. Fiberoptic intubation should therefore be used not only in patients with difficult airway, hypertension, ischemic heart disease, or cerebrovascular atherosclerosis, but also it is recommended for all patients for whom nasotracheal intubation is indicated.
Related Concept Videos
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Inhalational Anesthetics: Overview

