Related Experiment Video
Updated: Aug 23, 2026

A Recovery Cardiopulmonary Bypass Model Without Transfusion or Inotropic Agents in Rats
Published on: March 23, 2018
Fluctuating CPAP (F-CPAP) versus conventional CPAP (C-CPAP) in dogs with blood aspiration
1Department of Anesthesiology, School of Medicine, Chiba University, Chiba, Japan.
Abstract:
Fluctuating CPAP(F-CPAP) is a combination of spontaneous ventilation and fluctuating PEEP, in which end-expiratory pressure (EEP) is periodically changed within a certain range. In a dog model with localized lung injury induced by the aspiration of non-heparinized blood (2 ml.kg(-1) body weight), we carried out a comparative study of the effects of F-CPAP in which the EEP was cyclically changed from 4 to 12 cmH(2)O with periods of 10 min and those of conventional CPAP with a fixed EEP of 8 cmH(2)O (C-CPAP), on hemodynamics and pulmonary oxygenation. The blood aspiration produced significant increases in the intrapulmonary shunt (Qsp/Qt), the alveolar-arterial difference of partial pressure of oxygen (A-aD o(2)), and the respiratory rate (RR). Although both F-CPAP and C-CPAP reduced Qsp/Qt and A-aD o(2) and RR, 7 dogs treated with F-CPAP showed a significantly greater recovery of Qsp/Qt and A-aD o(2) than 7 dogs treated with C-CPAP. There were no significant differences in hemodynamic variables between the two groups. These results suggest that F-CPAP is more useful in the treatment of some kinds of hypoxic respiratory failure due to uneven distribution of lung injury.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiopulmonary Resuscitation II: ACLS Airway Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...