Related Experiment Video
Updated: Jul 22, 2026

An Experimental Paradigm for the Prediction of Post-Operative Pain (PPOP)
Published on: January 27, 2010
Maternal satisfaction to epidural and spinal anesthesia for cesarean section
Wacharin Sindhvananda1, Ruenreong Leelanukrom, Oraluxna Rodanant
1Department of Anesthesiology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
Background And Objective:
The differences between epidural (EA) and spinal (SA) anesthesia that can affect maternal satisfaction are the procedures, quality of anesthesia and postoperative events. Dominantly, postoperative events such as postdural puncture headache, pruritus and nausea or vomiting after spinal anesthesia are claimed to be its disadvantages. However, maternal satisfactory perception to theses two techniques has not been revealed. The authors' purpose was to compare maternal satisfaction regarding the techniques and their outcomes between EA and SA by the developed valid and reliable tool.
Material And Method:
Patients were randomly classified into two groups: epidural (Group E, n=56) and spinal (Group S, n = 58). Epidural and spinal anesthesia were administered with bupivacaine, 20 mL 0.5% with 1:200,000 epinephrine combined with two doses of 5 mg morphine and hyperbaric bupivacaine 2.2-2.4 mL 0.5% combined with 0.2 mg morphine respectively. Guidelines for treatment of intraoperative and postoperative events, which might be the confounding factors, were set up. Maternal satisfaction was evaluated by the 11-item, qualified, self-administered questionnaire comprised of 4 common factors. The score of 0-10 Visual analog scale was used to access the degree of satisfaction. Trained personnel performed data collections in the post-anesthesia care unit and ward. The means of the factor and total satisfaction scores were compared between the two groups by Mann Whitney U test. A p-value < 0.05 considered significant.
Results:
There was no statistical difference in the factor scores between the two groups. The total satisfactory score was 89.48 +/- 9.31 and 90.03 +/- 11.26 in Group E and S respectively. No statistical difference of the total satisfaction score was detected.
Conclusion:
There was no difference in maternal satisfaction regarding to the techniques and the outcomes between EA and SA.
Related Concept Videos
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Parenteral Anesthetics: Overview