Related Experiment Video
Updated: Jul 31, 2026

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
Published on: December 15, 2015
Development of a high-performance liquid chromatographic method with electrochemical detection for the determination
Ulla Rückert1, Karin Eggenreich, Reinhold Wintersteiger
1Institute of Pharmaceutical Chemistry and Pharmaceutical Technology, Karl-Franzens-University Graz, Schubertstrasse 1, 8010 Graz, Austria.
Abstract:
An HPLC method with electrochemical detection for the determination of hyperforin extracts without using additional sample precleaning has been developed and validated. The hyperforin solutions were separated isocratically using a mobile phase consisting of 10% ammonium acetate buffer (0.5 M, pH 3.7)-MeOH-acetonitrile (10:40:50, v/v) at a flow rate of 0.8 mL/min. Hyperforin was detected amperometrically with a glassy carbon electrode at a potential of +1.1 V versus Ag/AgCl/3 M potassium chloride reference electrode. Under these conditions, a plot of integrated peak area versus concentration of hyperforin was found to be linear over the range of 0.054-5.4 microg/mL, with a relative standard deviation of 2.2-8.6%. The limit of detection was 0.050 ng on column. The determination of the hyperforin content in a commercially available St. John's Wort preparation exhibited a mean content of 1.56 mg. Recovery experiments led to a mean recovery rate of 97 +/- 5.8%. The proposed method is not time-consuming, sensitive and reproducible and is therefore suitable for routine analysis of hyperforin in herbal medicinal products.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Electrophoresis: Overview
There...