Related Experiment Video
Updated: Aug 23, 2026

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Direct detection of biomolecules in a capillary electrophoresis-chemiluminescence detection system
Kazuhiko Tsukagoshi1, Koji Nakahama, Riichiro Nakajima
1Department of Chemical Engineering and Materials Science, Faculty of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan. ktsukago@mail.doshisha.ac.jp
Abstract:
Direct detection of biomolecules, such as alpha-amino acids, peptides, and proteins, was accomplished using a capillary electrophoresis-chemiluminescence detection system, in which a luminol-hydrogen peroxide-Cu(II)-catalyzed chemiluminescence reaction was utilized. Biomolecules migrated in the capillary, where they mixed with luminol and the Cu(II) catalyst included in the running buffer. The capillary outlet was inserted into a batch-type chemiluminescence detection cell with hydrogen peroxide-supplemented electrolyte solution. Chemiluminescence was observed at the tip of the capillary outlet. The chemiluminescence peak from biomolecules appeared due to the enhancement of Cu(II) catalytic activity for luminol-hydrogen peroxide chemiluminescence. The Cu(II) was more catalytically active when it interacted with biomolecules forming Cu(II)-biomolecule complexes. In this study, biomolecules were directly separated and detected in a capillary electrophoresis-chemiluminescence detection system. Twenty alpha-amino acids, 4 peptides, and 11 proteins were examined. Most of them were detected with satisfactory CL intensity response. Glutamic acid, an alpha-amino acid, was detected at concentrations ranging from 2.0 x 10(-7) to 1.2 x 10(-5) M with a detection limit (S/N = 3) of 1.0 x 10(-7) M (0.6 fmol). Glycylglycine, a peptide, was detected at concentrations ranging from 1.7 x 10(-7) to 1.2 x 10(-5) M with a detection limit (S/N = 3) of 1.7 x 10(-7) M (0.9 fmol). Hemoglobin, a heme protein, in which the heme structure was independently catalytically active, was detected at concentrations ranging from 1.2 x 10(-7) to 1.0 x 10(-5) M with a detection limit (S/N = 3) of 1.2 x 10(-7) M (0.6 fmol). Representative mixtures of alpha-amino acids and peptides were well detected with superior separation.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
