Evaluation of differences between observers and automatic-manual measurements in calculation of Doppler parameters
Birsen Unal1, Sebnem Bagcier, Ilknur Simsir
1Department of Radiology, Kirikkale University School of Medicine, Suleyman Demirel Hospital, Kirikkale, Turkey. birsenunal@hotmail.com
Objective:
We aimed to search for differences between observers and automatic and manual measurements in calculations of Doppler parameters.
Methods:
The middle cerebral artery (MCA), central retinal artery, ophthalmic artery (OA), common carotid artery (CCA), vertebral artery (VA), popliteal artery (PA), interlobar renal artery (IRA), and arcuate renal artery (ARA) were evaluated in 20 healthy subjects bilaterally. Peak systolic velocity (PSV), end-diastolic velocity (EDV), time-averaged maximum velocity (TAMAX), resistive index (RI), and pulsatility index (PI) were measured from the same spectrum manually by 3 observers and automatically. Results of 4 measurements were compared by analysis of variance and Pearson tests.
Results:
The comparison of the 4 measurements revealed significant differences for most parameters except TAMAX of the OA, VA, and ARA and PSV, EDV, and PI of the PA. An automatic calculator yielded lower PSV, RI, and PI values (except the MCA and PA) and higher EDV values compared with manual measurements. The magnitudes of difference were in the range of 1% to 16% for velocities and 4% to 14% for RI and PI. The means of difference were 3.185 cm/s for PSV of the CCA and 0.054 for RI of the IRA. Correlation was high for PSV, EDV, and TAMAX in all arteries (except TAMAX of PA) and relatively low for PI and RI in most of the arteries.
Conclusions:
Although our study was performed on healthy subjects, our results showed that, in most cases, readers and the automatic approach disagreed on evaluation of Doppler parameters. This may be important in preventing false diagnoses in cases with Doppler values close to upper limits and may necessitate establishment of new limits for each method.
Related Concept Videos
Doppler Effect - II
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Differential Leveling
Distance Corrections
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.