Effects of altered volume loading on left ventricular hemodynamics and diastolic filling during hemodialysis

Kuo-Chun Hung1, Husan-Li Huang, Chi-Ming Chu

  • 1Second Section of Cardiology, Department of Medicine, Chang Gung Memorial Hospital, Chang Gung University, College of Medicine, Taoyuan, Taiwan.

Renal Failure
|August 4, 2004
PubMed
Abstract

Related Concept Videos

Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this measurement...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
Heart Failure II: Pathophysiology01:29

Heart Failure II: Pathophysiology

Systolic Heart Failure and Compensatory MechanismsSystolic heart failure (also termed HFrEF, Heart Failure with Reduced Ejection Fraction) is the most prevalent type of heart filure. It results in a decreased volume of blood being pumped from the ventricle. The aortic arch and carotid sinuses have baroreceptors that detect reduced blood pressure, triggering the sympathetic nervous system (SNS) to release epinephrine and norepinephrine. Initially, this response aims to boost heart rate and...
Regulation of Stroke Volume01:27

Regulation of Stroke Volume

The regulation of stroke volume, which is the amount of blood the heart pumps out during each heartbeat, is critical for maintaining a healthy circulatory system. Stroke volume is influenced by three main factors: preload, contractility, and afterload.
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output01:22

Cardiac Output II: Effect of Stroke Volume on Cardiac Output

Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...