High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
High-performance liquid chromatography-ultrasonic nebulizer high-power nitrogen microwave-induced plasma mass
Amit Chatterjee1, Yasuyuki Shibata, Hiroaki Tao
1Environmental Chemistry Division, Environmental Chemodynamics Section, National Institute for Environmental Studies, 16-2 Onogawa, Ibaraki 305-0053, Tsukuba, Japan. amit@udel.edu
Abstract:
The coupling of a high-power nitrogen (N2) microwave-induced plasma (MIP) mass spectrometry--(MS) (1.3 kW) with high-performance liquid chromatography, connected with concentric nebulizer (CN), ultrasonic nebulizer (USN) and a hydride generation (HG) systems, for the optimization and determination of selenium compounds, has been carried out. The MIP-MS system fulfils the ideal requirement being an on-line real-time chromatographic detector for Se speciation analysis. Interchanging of MIP-MS system fabricated nebulizer (concentric) with an ultrasonic nebulizer increases about 3.4-12 (peak height) and 6.5-10 (peak area) times ion signals for the selenium compounds. The detection limits for selenate, selenite, trimethylselenonium ion (TmSe), selenomethionine (Semet) and selenoethionine (Seet) (in Milli-Q-water) obtained with the optimized HPLC-USN-N2MIP-MS system are 0.11, 0.14, 0.09, 0.14 and 0.10 microg L(-1), respectively, about 12-48 times lower than the HPLC-CN-MIP-MS and 1.5-4.4 (peak height) times lower compared to the HPLC-CN-inductively coupled plasma (ICP)-MS coupling. Considering peak area, the repeatability (R.S.D. for three successive analyses) and intermediate precision (R.S.D. for three successive analyses performed on three different days), achieved for five Se compounds are 0.8-5.6, and 1.1-5.9%, comparable with the HPLC-CN-ICP-MS, HPLC-HG-MIP-MS and HPLC-CN-MIP-MS systems. The combined HPLC-USN-N2MIP-MS has been adequately applied for the determination of Se compounds in certified National Institute for Environmental studies human urine CRM No. 18. The results reasonably agree with the HPLC-CN-ICP-MS values. This encouraging combination may be an alternative ion source of mass spectrometry for coming generation in regard to the selenium speciation analysis.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Emission Spectroscopy: Instrumentation