Related Experiment Video
Updated: Aug 23, 2026

A Robust Single-Particle Cryo-Electron Microscopy (cryo-EM) Processing Workflow with cryoSPARC, RELION, and Scipion
Published on: January 31, 2022
Low-resolution real-space envelopes: improvements to the condensing protocol approach and a new method to fix the
1Beckman Laboratories for Structural Biology, Department of Cell Biology, Stanford University School of Medicine, CA 94305, USA.
Abstract:
The condensing-protocol strategy for obtaining low-resolution real-space envelopes of macromolecules from native Fourier intensities alone was recently reported [Subbiah (1991). Science, 252, 128-133]. The present work introduces three improvements to the original methodology. In terms of the j index, which was defined as the crude ratio of correctly placed scatterers to those incorrectly placed, these changes collectively contribute to j values that range from 8 to 28 and in one case even infinity. This compares with the previously reported values of 1.9 and 2.6. Nevertheless, under different conditions, both the original and the current improved condensing protocol can preferentially converge on the solvent or the matter region. Since such control is not absolute there still remains a certain amount of ambiguity in deciding whether the congealed gas represents bulk solvent or bulk matter. To overcome this ambiguity, a simple method based on the systematic placement of point scatterers on a grid lattice within and without the envelope is presented. This 'sign-fixing' method is shown to work with both perfect envelopes as well as the cruder envelopes produced by the improved condensing protocol. The new methodology is illustrated using four macromolecular examples.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Upsampling
Distance Corrections
Super-resolution Fluorescence Microscopy
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
