Surface modification of an ethylene-acrylic acid copolymer film: grafting amine-terminated linear and branched architectures
Related Experiment Video
Updated: Jan 24, 2026

Light-induced Patterning and Grafting for Slippery Surfaces based on Silane-coated Nanoporous Structures
Published on: November 14, 2025
Amol V Janorkar1, Ning Luo, Douglas E Hirt
1Department of Chemical Engineering and Center for Advanced Engineering Fibers & Films, Clemson University, Clemson, South Carolina 29634-0909, USA.
Abstract:
Polymer films can be tailored for a specific application by modifying their surface properties. In this study, linear and branched architectures were grafted to ethylene-acrylic acid (EAA) copolymer films using the so-called grafting from approach. Dicyclohexylcarbodiimide was used to activate the carboxylic acid functionality on the surface of the EAA copolymer film before reacting it with selected di- and tri-amine compounds. The carboxylic acid functionality was subsequently regenerated by reacting the amine-grafted film with succinic anhydride. These reaction steps were then repeated to create the linear and branched architectures on the EAA film surface. The film surface resulting from each reaction step was analyzed using attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and contact angle measurements. A systematic analysis of the ATR-FTIR results was performed to estimate the average conversion of the reaction schemes and to explain the observed contact angle results. A significant reduction in water contact angle for the EAA film grafted with a branched architecture was observed. The EAA film grafted with a linear architecture showed a marginal reduction in water contact angle when ethanol was used as a solvent for ethylenediamine. When the solvent for ethylenediamine was changed to water, the contact angle decreased noticeably. However, analysis of control films showed that the reduction in the contact angles was due to the solvent treatment. In the case of branched architectures, such reduction in contact angle due to the solvent treatment was not observed. Several control experiments were performed to ensure that the reduction in the contact angles was in fact due to the grafted species and not due to exposure to various solvents used in the reaction scheme.
Related Concept Videos
Histone Modification
Acetylation
The enzyme histone acetyltransferase adds acetyl group to the histones. Another enzyme, histone...
Termination of Translation
Amino acids
Amines to Amides: Acylation of Amines
Next, the second equivalent of amine serves as a Brønsted base and deprotonates the quaternary...
Characteristics and Nomenclature of Copolymers
Preparation of Amines: Alkylation of Ammonia and Amines
Each alkylation step makes the nitrogen center more nucleophilic, which triggers successive alkylations until a quaternary ammonium salt is formed. Considering...

