Cardiac Pressure-Volume Loop Analysis Using Conductance Catheters in Mice
Published on: September 17, 2015
Cardiac output monitoring by pressure recording analytical method in cardiac surgery
Pierpaolo Giomarelli1, Bonizella Biagioli, Sabino Scolletta
1Department of Surgery and Bioengineering, Thoracic and Cardiovascular Unit, University of Siena, Viale Bracci 1, 53100 Siena, Italy.
Objective:
A less-invasive method has been developed that may provide an alternative to monitor cardiac output from arterial pressure: beat-to-beat values of cardiac output can be obtained by pressure recording analytical method (PRAM). The purpose of this study was to assess the reliability of cardiac output determination by PRAM in cardiac surgery.
Methods:
Cardiac output was measured in 28 patients undergoing coronary artery bypass grafting at 15 min after anaesthesia induction, 30 min after extracorporeal circulation, 1 and 3 h after arrival in the intensive care unit using thermodilution (ThD) method through a pulmonary artery catheter and PRAM. ThD cardiac output was calculated as the mean of five separate measurements. PRAM provided beat-by-beat cardiac output data continuously throughout the study and the cardiac output values displayed on a dedicated personal computer at each time point were recorded. Correlations were calculated and differences were compared by Bland-Altman analysis.
Results:
A total of 112 measurements were obtained. Cardiac output ranged from 2.3 to 7.4 l/min, and a good linear correlation (R2=0.78, P<0.0001) was found between ThD and PRAM. The highest degree of correlation (R2=0.86) was obtained at 3 h after arrival in the intensive care unit. The lower degree of correlation (R2=0.70) was obtained 30 min after extracorporeal circulation. At Bland-Altman analysis, the overall estimates of cardiac output measured by PRAM closely agreed with ThD (mean difference, 0.027; standard deviation, 0.43; limits of agreement, -0.83 and +0.89).
Conclusions:
Under the studied conditions, our results demonstrate good agreement between PRAM data and ThD measurements, and this new method has shown to be accurate for real-time monitoring of cardiac output in cardiac surgery. Further studies will be required to assess this method in higher-risk patients and in the setting of haemodynamic instability or arrhythmias. This is the first study designed to assess the accuracy of PRAM in cardiac surgery.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)