Capillary Electrophoresis to Monitor Peptide Grafting onto Chitosan Films in Real Time
Published on: October 26, 2016
Analysis of synthetic peptides by capillary electrophoresis: effect of organic solvent modifiers and variable
Yuanzhong Yang1, Reinhard I Boysen, Milton T W Hearn
1Australian Research Council Special Research Centre for Green Chemistry, Australian Centre for Research on Separation Science, Monash University, Victoria, Australia.
Abstract:
In this study, procedures based on volatile ammonium acetate buffer electrolytes of high pH value containing different organic solvent modifiers have been developed to achieve very high efficiency separations of histidine-containing synthetic peptides by high-performance capillary electrophoresis (HPCE) employing untreated fused silica capillaries. Different organic solvents, including acetonitrile, methanol and ethanol, at high volume fractions were used to modify the composition of the background buffer electrolyte. With the peptides investigated, it was found that methanol had the greatest effect in terms of enhancement of separation efficiency, as determined from the evaluation of theoretical plate numbers, N, of these HPCE systems. On the other hand, separation selectivities, e.g. the alpha(ij) values, did not change significantly as the volume fraction, psi, of the organic solvents was increased up to psi = 60% (v/v). Under these conditions, very rapid, e.g. 1-2 min, separation times could be still achieved. Compared to the effect of carrying out the separation of these peptides at constant voltage, a dramatic increase in the separation efficiency was also achieved by applying a linear voltage gradient during the HPCE experiment. Under optimal conditions of organic solvent composition and linear voltage gradient ramps, very high peak efficiencies for the studied set of synthetic peptides with N values of approximately 2-3 million theoretical plates per meter could be routinely obtained with fast analysis times. Moreover, these buffer electrolyte conditions are compatible with direct interfacing of the HPCE effluent to electrospray ionisation and ion trap mass spectrometers, thus expanding the analytical capabilities of these HPCE systems.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...