Related Experiment Video
Updated: Aug 17, 2026

Real-Time Assessment of Spinal Cord Microperfusion in a Porcine Model of Ischemia/Reperfusion
Published on: December 10, 2020
Thromboembolic deterrent stockings fail to prevent hypotension associated with spinal anaesthesia for elective
P K Sood1, P J Cooper, M Z Michel
1Department of Anaesthesia, Poole Hospital NHS Trust, Poole, UK.
This study was carried out to determine whether the use of thrombo-embolic deterrent (TED) stockings, in combination with an intravenous crystalloid preload, would prevent hypotension following spinal anaesthesia for caesarean section. Fifty parturients undergoing elective caesarean section under spinal anaesthesia were randomly allocated into two groups. TED stockings were applied to the study group 1 h before spinal anaesthesia but none were applied to the control group. Both groups received a crystalloid preload of 15 ml kg(-1) over 15 min before spinal injection. Significant hypotension, defined as an absolute value of systolic arterial pressure (SAP) of less than 90 mmHg and a decrease of more than 20% from baseline SAP was treated with 3 mg bolus of ephedrine as required. The difference in SAO between the two groups was not statistically significant. In the control group, 80% of parturients required ephedrine as opposed to 56% in the TED group; a difference that was also not statistically significant.
This study was carried out to determine whether the use of thrombo-embolic deterrent (TED) stockings, in combination with an intravenous crystalloid preload, would prevent hypotension following spinal anaesthesia for caesarean section. Fifty parturients undergoing elective caesarean section under spinal anaesthesia were randomly allocated into two groups. TED stockings were applied to the study group 1 h before spinal anaesthesia but none were applied to the control group. Both groups received a crystalloid preload of 15 ml kg(-1) over 15 min before spinal injection. Significant hypotension, defined as an absolute value of systolic arterial pressure (SAP) of less than 90 mmHg and a decrease of more than 20% from baseline SAP was treated with 3 mg bolus of ephedrine as required. The difference in SAO between the two groups was not statistically significant. In the control group, 80% of parturients required ephedrine as opposed to 56% in the TED group; a difference that was also not statistically significant.
More Related Videos
Related Concept Videos
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Peripheral Artery Disease V: Postoperative Nursing Management
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care

