Related Experiment Videos

Improvement of Laih and Yen's multisignature scheme

Qi Xie1, Xiu-yuan Yu

  • 1Department of Mathematics, Zhejiang University, Hangzhou 310027, China. qixie@hztc.edu.cn

Related Concept Videos

Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first column of the Routh...
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Law of Rational Indices01:29

Law of Rational Indices

The Law of rational indices is a fundamental principle in the field of crystallography. According to this law, the intercepts of a crystal face along the crystallographic axes (the three-dimensional axes along which a crystal is measured) can be expressed as either equivalent to the unit intercepts (a, b, c) or simple whole number multiples of them. These multiples are typically denoted as na, n'b, and n''c, where n, n', and n'' are simple whole numbers.To illustrate, consider a crystal with...
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Standard Entropy Change for a Reaction03:00

Standard Entropy Change for a Reaction

Entropy is a state function, so the standard entropy change for a chemical reaction (ΔS°rxn) can be calculated from the difference in standard entropy between the products and the reactants.
Fineness Modulus01:19

Fineness Modulus

The fineness modulus (FM) of aggregate is a numerical index that measures the coarseness or fineness of the particles. It is calculated by adding the cumulative percentages of aggregate retained on each of a specified series of sieves and dividing the sum by 100.
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...