Related Experiment Video
Updated: Aug 22, 2026

Non-invasive Imaging and Analysis of Cerebral Ischemia in Living Rats Using Positron Emission Tomography with 18F-FDG
Published on: December 28, 2014
Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET
Kristof Baete1, Johan Nuyts, Koen Van Laere
1Department of Nuclear Medicine, Katholieke Universiteit Leuven, B-3000 Leuven, Belgium. Kristof.Baete@uz.kuleuven.ac.be
Unlabelled:
FDG-PET contributes to the diagnosis and management of neurological diseases. In some of these diseases, pathological gray matter (GM) areas may have a reduced FDG uptake. Detection of these regions can be difficult and some remain undiscovered using visual assessment. The main reason for this detection problem is the relatively small thickness of GM compared to the spatial resolution of PET, known as the partial volume effect. We have developed an anatomy-based maximum-a-posteriori reconstruction algorithm (A-MAP) which corrects for this effect during the reconstruction using segmented magnetic resonance (MR) data. Monte-Carlo based 3-D brain software phantom simulations were used to investigate the influence of the strength of anatomy-based smoothing in GM, the influence of misaligned MR data, and the effect of local segmentation errors. A human observer study was designed to assess the detection performance of A-MAP versus post-smoothed maximum-likelihood (ML) reconstruction. We demonstrated the applicability of A-MAP using real patient data. The results for A-MAP showed improved recovery values and robustness for local segmentation errors. Misaligned MR data reduced the recovery values towards those obtained by post-smoothed ML, for small registration errors. In the human observer study, detection accuracy of hypometabolic regions was significantly improved using A-MAP, compared to post-smoothed ML (P < 0.004). The patient study confirmed the applicability of A-MAP in clinical practice.
Conclusion:
A-MAP is a promising technique for voxel-based partial volume correction of FDG-PET of the human brain.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)