Related Experiment Video
Updated: Aug 17, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Patient and operator dose during fluoroscopic examination of swallow mechanism
M T Crawley1, P Savage, F Oakley
1Radiology Department and Speech and Language Therapy Department, Stoke Mandeville Hospital, Mandeville Road, Aylesbury, Buckinghamshire HP21 8AL, UK.
Abstract:
Dose-area product (DAP) measurements were made for 21 patients undergoing a modified barium swallow. The procedures were performed by a radiologist and speech and language therapist, to characterize swallowing disorders in patients with head or spinal injury, stroke, other neurological conditions or simple globus symptoms, in order to inform feeding strategies. The DAP values were used to estimate effective dose to the patient, in order to provide a measure of the radiation risk associated with the procedure. Whole body doses to operators, together with equivalent doses to extremities and eyes were also measured to inform the employer's risk assessment. Median DAP for the series was 3.5 (3.1-5.2) Gycm(2) with a corresponding effective dose to the patient of 0.85 (0.76-1.3) mSv, and a low associated risk, mainly of cancer induction, of about 1 in 16 000. The organ receiving the greatest dose was the thyroid, with a calculated median equivalent dose of 13.9 (12.3-20.7) mSv. Median screening time was 3.7 (2.5-4.3) min. Mean operator doses were 0.5 mSv equivalent dose (eyes), 0.9 mSv (extremities), and less than 0.3 mSv whole body dose. Extrapolating for an annual workload of 50 patients per year, this work will lead to annual operator doses of less than 0.6 mSv whole body dose, and approximately 1 mSv equivalent dose (eyes) and 1.8 mSv (extremities), against corresponding legal dose limits of 20 mSv, 150 mSv and 500 mSv, respectively.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography