Related Experiment Video
Updated: Jul 31, 2026

Calorespirometry: A Powerful, Noninvasive Approach to Investigate Cellular Energy Metabolism
Published on: May 31, 2018
Validation of the BodyGem hand-held calorimeter
E L Melanson1, L B Coelho, Z V Tran
1Center for Human Nutrition, University of Colorado Health Sciences Center, Denver, CO 80262, USA. Ed.melanson@uchsc.edu
Objective:
To assess the validity and reliability of a hand-held indirect calorimeter.
Design:
Resting metabolic rate (RMR) was measured on two separate mornings.
Subjects:
A heterogeneous sample of 41 healthy adults.
Measurements:
RMR using both a metabolic cart (Sensormedics 2900, SM-2900) and a hand-held indirect calorimeter (BodyGem, BG).
Results:
There were no trial-to-trial differences in RMR measured by the BG (6756+/-163 vs 6697+/-163 kJ/day) or the SM-2900 (6400+/-163 vs 6396+/-167 kJ/day). RMR measured by the BG was significantly higher than that measured by the SM-2900 during both trials. In a sample of 10 subjects, the energy cost of holding the BG in position was determined to be (0.17+/-0.04 kJ/min, or 255+/-84 kJ/day). After applying this adjustment, the differences between systems were no longer significant during trial 1 (mean difference=101+/-67 kJ/day) or trial 2 (46+/-75 kJ/day). In overweight and obese individuals, RMR measured by the BodyGem was more accurate than that estimated by the Harris-Benedict equations.
Conclusion:
The BodyGem provides valid and reliable measurements of RMR. The BodyGem produces significantly higher values than the Sensor Medics 2900 indirect calorimeter, with the increase largely due to an increased energy demand required to hold the BG in position.
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Related Concept Videos
Constant Pressure Calorimetry
Constant Volume Calorimetry
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Calorimetry