Closed suctioning system reduces cross-contamination between bronchial system and gastric juices
Werner Rabitsch1, Wolfgang J Köstler, Wolfgang Fiebiger
1Intensive Care Unit, Department of Internal Medicine I, University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria.
Abstract:
In this prospective, randomized study, we evaluated whether a closed suctioning (CS) system (TrachCare) influences crossover contamination between bronchial system and gastric juices when compared with an open suctioning system (OS). The secondary aims were an analysis of the frequency of ventilator-associated pneumonia (VAP) and an analysis of alteration in gas exchange. Antibiograms were performed from tracheal secretions and gastric juice aspirates on Days 1 and 3 of intubation in 24 patients in a medical intensive care unit. Five cross-contaminations were observed in the OS group on Day 3 versus Day 1; the 5 strains shared common genotypes as determined by random amplification of polymorphic DNA. No cross-contaminations were seen in the CS group (P = 0.037). VAP occurred in 5 patients of the OS group but in none of the CS group patients (P = 0.037). Spao(2) decreased significantly in the OS group compared with presuctioning values--the opposite of the CS group. Whereas presuctioning values were comparable between groups, postsuctioning Spao(2) was significantly higher in the CS group. CS significantly reduced cross-contamination between bronchial system and gastric juices and reduced the incidence of VAP when compared with OS. Hypoxic phases can be reduced by the help of CS.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...