Related Experiment Video
Updated: Aug 22, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Abdominal aortic aneurysms at multi-detector row helical CT: optimization with interactive determination of scanning
Lisa M Ho1, Rendon C Nelson, John Thomas
1Department of Radiology, Duke University Medical Center, Box 3808, Room 2529 Blue Zone, Durham, NC 27710, USA. ho000004@mc.duke.edu
Purpose:
To prospectively evaluate a technique for optimizing aortoiliac enhancement at multi-detector row helical computed tomography (CT) with both the scanning delay and contrast medium dose determined by using an interactive method.
Materials And Methods:
Forty-five patients with abdominal aortic aneurysm were randomized to undergo multi-detector row helical CT with either an interactive protocol (n = 23) or a standard protocol (n = 22). Scanning delays in all patients were determined with automated triggering. Patients in the standard protocol group received 150 mL of contrast medium intravenously at 4 mL/sec. The same injection rate was used for the interactive protocol group, but the dose was reduced with discontinuation of injection at start of scanning. Quantities of contrast medium used and contrast-enhanced aortic attenuation achieved were compared. Aortoiliac enhancement was evaluated qualitatively by using a five-point scale (1 = poor, 5 = excellent). Quantitative and qualitative data were analyzed with the two-tailed t test and Wilcoxon rank sum test, respectively, to determine significance of differences (P <.05).
Results:
Data from six patients were excluded because of technical errors. Data were analyzed from 20 patients in the interactive protocol group and 19 in the standard protocol group. Mean contrast medium volume was 107 mL +/- 20 (standard deviation) in the interactive protocol group and 148 mL +/- 3 in the standard protocol group (P <.001). Mean contrast-enhanced attenuation at initial, peak, and final measurements was 257 HU +/- 38, 285 HU +/- 46, and 269 HU +/- 54, respectively, for the interactive protocol group, and 261 HU +/- 65, 288 HU +/- 66, and 269 HU +/- 61 for the standard protocol group (P >.05). Mean qualitative enhancement scores for interactive and standard protocol groups were 4.47 and 4.44, respectively (P =.47).
Conclusion:
The interactive method is a simple, efficient, and reproducible way to optimize aortoiliac enhancement while reducing contrast medium dose.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
