Related Experiment Video
Updated: Aug 22, 2026

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Capillary isoelectric focusing of proteins utilizing poly(vinylpyrrolidone)- and plexiglas-coated columns
Anders Palm1, Maximiliano Zaragoza-Sundqvist, György Marko-Varga
1Department of Chemistry, Indiana University, Bloomington, IN 47405, USA.
Abstract:
Fused-silica capillaries chemically derivatized with silane/poly(vinylpyrrolidone) (PVP) or dynamically modified with plexiglas [poly(methyl methacrylate)] were prepared and evaluated with regard to column stability and separation performance for capillary isoelectric focusing of standard proteins. The PVP coating showed the better stability and was good for at least 100 runs while the plexiglas coating started to deteriorate after about 30 runs. The time spent for the plexiglas coating is about 40 minutes while the PVP coating requires two days. The migration time reproducibility was better with the PVP capillary (RSD 0.7-1.6%, n = 5) compared to the plexiglas-coated column (RSD 1.2-2.9%, n = 5) while peak area and height varied over a similar interval (RSD 2-28.1% area; 0.9-22.7% height, n = 5). The two most consistent proteins in this evaluation, viz. myoglobin A and carbonic anhydrase II, showed linear dynamic ranges between 5-150 and 5-50 microg/mL, and limits of detections at 2 and 1 microg/mL, respectively, employing UV detection at 280 nm.
More Related Videos
09:57Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing (IEF) Method
Published on: June 14, 2020
10:57Fast and Sensitive Colloidal Coomassie G-250 Staining for Proteins in Polyacrylamide Gels
Published on: August 3, 2009
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography
Electrophoresis: Overview
There...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...