Related Experiment Video
Updated: Aug 22, 2026

Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology
Published on: October 3, 2016
Autoclave use in dental practice in the Republic of Ireland
C M Healy1, H P O Kearns, W A Coulter
1Department of Oral Surgery, Oral Medicine and Oral Pathology, Dublin Dental School and Hospital, Lincoln Place, Dublin 2, Ireland. claire.healy@dental.tcd.ie
Aims:
To assess by postal questionnaire, cross-infection control methods, especially sterilisation procedures, of 700 general dental practitioners in the Republic of Ireland, and to biologically monitor steam pressure sterilisers or autoclaves in their practices.
Main Outcome Measures:
Methods of instrument cleaning and sterilisation, autoclave efficacy.
Results:
A response rate of 40% with all, except one practitioner, using steam sterilisation. 49% also reported the use of chemical sterilisation with a quarter of these using glutaraldehyde. However, instrument soaking time varied greatly from 2.5 minutes to 74 hours. Methods of instrument cleaning prior to autoclaving were as follows: scrubbing by hand 41.5%, ultrasonic cleaning 7.0%, combination of both 50%. 52.9% of the respondents did not autoclave their dental handpieces and only 44.7% disinfected impressions before sending them to the laboratory. The autoclaves of thirty practitioners (11.3%) did not pass the initial biological test. Following counselling about possible causes of failure, four autoclaves (1.5%) failed a repeat biological test. However, seven practitioners did not return the repeat biological test.
Conclusions:
Some aspects of recommended cross-infection control procedures are well adhered to, e.g. instrument cleaning, but further education is required in certain key areas, in particular the use of chemical sterilisation, dental handpiece autoclaving and impression disinfection. There is also a need to increase awareness of the importance of routine autoclave servicing and calibration, along with validation and monitoring.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...