Doppler assessment of cardiac function at 11-14 weeks' gestation in fetuses with normal and increased nuchal
I C Huggon1, O Turan, L D Allan
1Harris Birthright Research Centre for Fetal Medicine, King's College Hospital, London, UK. ian.huggon@btinternet.com
Objective:
To investigate cardiac dysfunction as a potential underlying mechanism for increased nuchal translucency (NT) in fetuses with chromosomal abnormality or heart defects.
Methods:
Myocardial performance index (MPI) and atrioventricular valve E/A ratios for both sides of the heart were measured by Doppler echocardiography in fetuses at 11-14 weeks' gestation. The study groups consisted of 159 normal control fetuses, 199 otherwise normal fetuses but with increased NT > or = 4 mm, 142 fetuses with trisomy 21, 58 with trisomy 18, 19 with trisomy 13, 37 with Turner's syndrome and 24 with isolated heart defects. Groups were compared using Student's t-test and confidence intervals for differences between groups were calculated.
Results:
Otherwise normal fetuses with increased NT showed no difference in any of the cardiac Doppler parameters from normal controls. Mean E/A ratio was slightly but significantly increased in trisomy 21 fetuses compared with normal controls (0.604 vs. 0.578 on the right, P = 0.011; 0.581 vs. 0.542 on the left, P = 0.0001). E/A ratio was not significantly different between any of the other groups and the normals but there was a small increase in absolute E-wave velocity in trisomy 18 fetuses. MPI was significantly decreased in trisomy 21 fetuses, (0.330 vs. 0.378, P = 0.002 on the left) and also in Turner's syndrome fetuses (0.301 vs. 0.352 on the right, P = 0.04; 0.320 vs. 0.378 on the left, P = 0.034) implying better performance, but not in the other groups.
Conclusions:
The magnitude and/or direction of the differences shown do not support a major role for cardiac functional abnormality in the development of NT. Important cardiac dysfunction could not be demonstrated in association with increased NT in normal or abnormal fetuses.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...