Related Experiment Video
Updated: Aug 22, 2026

A Computational Modeling Approach to Investigate the Influence of Hyperthermia on the Tumor Microenvironment
Published on: December 1, 2023
Experimental studies of the thermal effects associated with radiation force imaging of soft tissue
Mark L Palmeri1, Kristin D Frinkley, Kathryn R Nightingale
1Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA. mark.palmeri@duke.edu
Abstract:
Many groups are studying acoustic radiation force-based imaging modalities to determine the mechanical properties of tissue. Acoustic Radiation Force Impulse (ARFI) imaging is one of these modalities that uses standard diagnostic ultrasound scanners to generate localized, impulsive, acoustic radiation force in tissue. This radiation force generates tissue displacements that are tracked using conventional correlation-based ultrasound methods. The dynamic response of tissue to this impulsive radiation force provides information about the mechanical properties of the tissue. The generation of micron-scale displacements using acoustic radiation force in tissue requires the use of high-intensity acoustic beams, and the soft tissue heating associated with these high-intensity beams must be evaluated to ensure safety when performing ARFI imaging in vivo. Experimental studies using thermocouples have validated Finite Element Method (FEM) models that simulate the heating of soft tissue during ARFI imaging. Spatial maps of heating measured with the thermocouples are in good agreement with FEM model predictions, with cooling time constants measured and modeled to be on the order of several seconds. Transducer heating during ARFI imaging has been measured to be less than 1 degrees C for current clinical implementations. These validated FEM models can now be used to simulate soft tissue heating associated with different transducers, beam spacing, focal configurations and thermal material properties. These experiments confirm that ARFI imaging of soft tissue is safe, although thermal response must be monitored when developing ARFI beam sequences for specific tissue types and organsystems.
More Related Videos
06:08Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
Absorption of Radiation
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...