An in vivo comparative study of the e-polytetrafluoroethylene vascular prostheses: Vitaflon and Gore-Tex
N B Dobrova1, A J Gorodkov, E S Sidorenko
1Bakulev Scientific Center of Cardio-vascular Surgery, 135, Rublevskoye schosse, 121552 Moscow, Russia.
Abstract:
A comparative study was performed in order to validate new Russian e-PTFE vascular prostheses Vitaflon (St. Petersburg, Russia). The Gore-Tex prostheses were chosen as a referential model. The prostheses were implanted in the venous and arterial positions in 13 dog experiments. After the implantation time was over a comprehensive histological and histochemical examination of excized specimens was performed. It was demonstrated that there is no difference in healing and functional properties between the two studied prostheses.